Corning UltraRibbon™ Plenum Gel-Free Cables continue the innovative breakthrough in indoor cable technology with a new generation of high-fiber-count single tube cables. The cable maximizes the use of critical duct space and can easily fit in 1.25-in inner duct.
A specially formulated flame-retardant jacket allows this cable to be used in indoor general purpose horizontal and plenum applications.
The cable consists of a single buffer tube containing a stack of 24- and 36-fiber ribbons that are easily separated by hand into two or three fiber ribbons, respectively.
Features And Benefits
• Fiber Category: Single-mode (OS2)
• Standards: according to National Electrical Code® (NEC®) Article 770
• Design and Test Criteria: ANSI/ICEA S-87-640
• Fiber Count: 288
• Fiber Coloring: Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua
• Ribbons per Tube: 12
• Fibers per Ribbon: 24
• Outer Jacket Color: Yellow
• Operation: -20 °C to 70 °C (-4 °F to 158 °F )
• Max. Tensile Strength: Short-Term 1320 N (300 lbf) / Long-Term 400 N (90 lbf)
• Weight: 359.49 kg/km (241.56 lb/1000 ft)
• RoHS: Free of hazardous substances according to RoHS 2011/65/EU
• Fiber Category:G.657.A1
• Wavelengths: 1310 nm / 1383 nm / 1550 nm
• Maximum Attenuation: 0.4 dB/km / 0.4 dB/km / 0.3 dB/km
• Precise fiber and ribbon geometries in a gel-free design
Excellent mass splicing yields
• Flame-retardant jacket
Rugged and durable
• Up to 504 fibers in a compact design
Easily fits in 1.25-in diameter inner duct
Standards
• Approvals and Listings National Electrical Code® (NEC®) OFNP, CSA FT-6, ICEA S-83-596
• Common Installations: Indoor plenum, riser and general building applications
• Flame Resistance: NFPA 262 (for plenum, riser and general building applications)